[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [IRCA] RG11
- Subject: Re: [IRCA] RG11
- From: "Mark Durenberger Mobile" <Mark4@xxxxxxxxxxxxxxx>
- Date: Thu, 28 Jul 2011 11:15:49 -0500
I would second the Cat 5e approach. I've done a number of controlled tests
and it outperforms RG-58 hands down, MW thru 10 meters, for noise
performance and signal loss. With shorter runs (50 feet or so) I haven't
needed baluns.
Mark Durenberger
-----Original Message-----
From: Craig Healy
Rather than use RG-11 I'd probably buy RG-8 that is suitable for being
buried. Even RG-58 would be OK if it's under 100 feet or so. It can be
bought with connectors already installed. Plug and play.
Another test I made is making a balun for each end and using CAT5 ethernet
network cable. It's balanced and gathers less noise or unwanted signals on
the way in. Also cheap and very easy to build.
_______________________________________________
IRCA mailing list
IRCA@xxxxxxxxxxxxxxxx
http://montreal.kotalampi.com/mailman/listinfo/irca
Opinions expressed in messages on this mailing list are those of the original contributors and do not necessarily reflect the opinion of the IRCA, its editors, publishing staff, or officers
For more information: http://www.ircaonline.org