[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [IRCA] Inland TP's
Interesting results Craig. It sounds as if the FLG-100LN isn't
functioning properly. (first thought...power supply?)
When you say "outperformed" was it in raw gain, signal to noise or ?
I'm not familiar with either the KB-5 or QB-18I. Are these no
longer in production?
best wishes,
Nick
At 14:17 17-09-16, you wrote:
....
I did some testing with transformers on my wnw Conti super loop this
morning. Between an FLG 100ln, a KB-5 MW/LW balun and an Erickson
QB-18I. Interestingly the KB-5 and QB-18I consistently outperformed
the FLG-100ln on the loop, with and without the use of the DX
Engineering RPA-1 preamp. The ALA 1530ln held it's own. I used JOUB
and 1566(presumed HLAZ) as the test frequencies. The test was
limited to challenging TP DX targets for the Midwest.
Nick Hall-Patch
Victoria, BC
Canada